Complex Power and Power Factor: GATE ECE practice questions with solutions
This topic covers real, reactive and complex power, power factor, correction with capacitors and conjugate matching. The 15 original questions follow the GATE EC format: 7 MCQ, 2 MSQ and 6 NAT, from 5 easy, 7 medium and 3 hard.
Three ideas to know:
- Real power is , which is the apparent power times the power factor.
- Real and reactive powers add across parallel loads. Power factors do not.
- Use phasors with the load voltage as reference; the line drop adds as a complex number.
It helps GATE EC and ECE students revising Networks for the exam or a semester test. Helpful background: Power triangle and Phasors. Start with the 5 easy questions, then work up to the 3 hard ones.
Related
Q.1
EasyMCQ1 mark
A single-phase load is supplied at rms and draws rms at a power factor of lagging. The real power absorbed by the load is
Show answer and solutionHide answer and solution
Answer: (D)
Key idea: Real power is VI\cos\phi, which is the apparent power times the power factor.
P = VI\cos\phi = 100\times5\times0.8 = 400\ \text{W}.
Check: the apparent power is S = 500\ \text{VA}, and Q = 500\times0.6 = 300\ \text{var}. Then \sqrt{400^2+300^2} = 500. ✓
Common mistake: Answering VI = 500 is the apparent power in VA, not the real power in W.
You need: rms values; power factor
Q.2
EasyMCQ1 mark
A load absorbs and (inductive). Its power factor is
Show answer and solutionHide answer and solution
Answer: (A)
Key idea: Power factor = P/|S|, and the sign of Q decides lagging or leading.
S = \sqrt{600^2+800^2} = 1000\ \text{VA}. The power factor is \frac{P}{S} = \frac{600}{1000} = 0.6. Since Q > 0, the current lags the voltage.
Common mistake: Using Q/S = 0.8 (the sine of the angle) gives (C). Using P/Q = 0.75 gives (B).
You need: Power triangle
Q.3
EasyNAT1 mark
A series - circuit with and is connected to a rms supply. The real power absorbed, in watts, is ______.
Numerical answer: type a number.
Show answer and solutionHide answer and solution
Answer: 1200 W (accepted 1195 to 1205)
Key idea: Real power is dissipated only in resistance: P = I^2R.
|Z| = \sqrt{3^2+4^2} = 5\ \Omega, so I = \frac{100}{5} = 20\ \text{A}. Only the resistor absorbs real power: P = I^2R = 400\times3 = 1200\ \text{W}.
Check: S = VI = 2000\ \text{VA} and \cos\phi = \frac{3}{5} = 0.6, so P = 2000\times0.6 = 1200\ \text{W}. ✓
Common mistake: Using V^2/R = 3333\ \text{W}, which ignores the inductor, or giving S = 2000 as the real power.
You need: Series impedance; I^2R power
Q.4
EasyMCQ1 mark
A load has voltage rms and current rms. The complex power absorbed by the load is
Show answer and solutionHide answer and solution
Answer: (B)
Key idea: Complex power is VI^*, with the current conjugated.
S = VI^*. The conjugate of the current is 5\angle+36.87^\circ, so S = 200\times5\angle36.87^\circ = 1000\angle36.87^\circ = 1000(0.8 + j0.6) = 800 + j600\ \text{VA}.
The current lags the voltage, so Q is positive (inductive).
Common mistake: Using VI without the conjugate gives 1000\angle-36.87^\circ = 800 - j600 (A).
You need: Phasors; complex conjugate
Q.5
EasyMSQ1 mark
Which of the following statements are correct?
One or more options are correct.
Show answer and solutionHide answer and solution
Answer: (A) and (B)
Key idea: P and Q combine as a vector sum in the power triangle, not as a scalar sum.
(A) is true: the voltage and current are 90^\circ apart, so the average of vi is zero. (B) is true: the voltage and current of a resistor are in phase. (C) is false: |S| = \sqrt{P^2+Q^2}, since P and Q are at right angles in the power triangle. (D) is false: with that convention a capacitor has Q < 0, meaning it supplies reactive power.
Common mistake: Adding P and Q arithmetically to get S.
You need: Power triangle; phase relations in L and C
Q.6
MediumMCQ2 marks
Two loads are connected in parallel across the same supply. Load 1 absorbs at lagging. Load 2 absorbs at unity power factor. The overall power factor seen by the supply is
Show answer and solutionHide answer and solution
Answer: (B)
Key idea: Real and reactive powers add across parallel loads. Power factors do not.
Load 1: S_1 = \frac{12}{0.6} = 20\ \text{kVA} and Q_1 = \sqrt{20^2-12^2} = 16\ \text{kvar} (lagging). Load 2: Q_2 = 0.
Totals: P = 28\ \text{kW} and Q = 16\ \text{kvar}, so S = \sqrt{784+256} = 32.25\ \text{kVA}. The power factor is \frac{28}{32.25} = 0.868, lagging because Q > 0.
Common mistake: Averaging the two power factors, \frac{0.6+1}{2} = 0.8, gives (A).
You need: Power triangle; additivity of complex power
Q.7
MediumNAT2 marks
A load of at lagging power factor is supplied at rms, . A capacitor is connected in parallel with the load to bring the power factor to unity. The capacitance required, in microfarads, is ______.
Numerical answer: type a number.
Show answer and solutionHide answer and solution
Answer: 298 µF (accepted 296 to 301)
Key idea: The capacitor must supply the load's reactive power: Q_C = \omega CV^2.
The load reactive power is Q = P\tan\phi = 20\times\frac{0.6}{0.8} = 15\ \text{kvar}. For unity power factor the capacitor must supply 15\ \text{kvar}, so X_C = \frac{V^2}{Q_C} = \frac{160000}{15000} = 10.667\ \Omega.
C = \frac{1}{\omega X_C} = \frac{1}{314.16\times10.667} = 2.984\times10^{-4}\ \text{F} = 298\ \mu\text{F}.
Check: Q_C = \omega CV^2 = 314.16\times2.984\times10^{-4}\times160000 = 15\ \text{kvar}. ✓
Common mistake: Using the apparent power 25\ \text{kVA} instead of Q gives 497\ \mu\text{F}.
You need: Reactive power; capacitor reactance
Q.8
MediumNAT2 marks
A load of operates at a power factor of lagging. A parallel capacitor bank is added to improve the power factor to lagging. The reactive power the capacitor bank must supply, in kvar, is ______.
Numerical answer: type a number.
Show answer and solutionHide answer and solution
Answer: 25.47 kvar (accepted 25.4 to 25.6)
Key idea: Q_C = P(\tan\phi_1 - \tan\phi_2), because P does not change.
Before correction: Q_1 = 30\tan(\cos^{-1}0.6) = 30\times1.3333 = 40\ \text{kvar}. After correction: Q_2 = 30\tan(\cos^{-1}0.9) = 30\times0.4843 = 14.53\ \text{kvar}.
The capacitor supplies the difference: Q_C = 40 - 14.53 = 25.47\ \text{kvar}.
Check: the new apparent power is \frac{30}{0.9} = 33.33\ \text{kVA}, and \sqrt{33.33^2-30^2} = 14.53\ \text{kvar}. ✓
Common mistake: Subtracting the power factors themselves, 30(0.9-0.6) = 9, which has no meaning.
You need: Power triangle; power factor correction
Q.9
MediumMCQ2 marks
A load impedance is connected to a rms supply. The real and reactive power absorbed are
Show answer and solutionHide answer and solution
Answer: (B)
Key idea: P = I^2R and Q = I^2X, with X > 0 for an inductor.
|Z| = 10\ \Omega, so I = 23\ \text{A}. Then P = I^2R = 529\times8 = 4232\ \text{W} and Q = I^2X = 529\times6 = 3174\ \text{var}, positive for an inductor.
Check: S = VI = 5290\ \text{VA}, and \sqrt{4232^2+3174^2} = 5290. ✓
Common mistake: Swapping P and Q gives (A). Quoting the apparent power 5290 as P gives (C).
You need: Impedance; complex power
Q.10
MediumNAT2 marks
A source of rms with internal impedance feeds a load impedance whose resistance and reactance can both be varied. The maximum average power that can be delivered to the load, in watts, is ______.
Numerical answer: type a number.
Show answer and solutionHide answer and solution
Answer: 833.3 W (accepted 832 to 835)
Key idea: For a complex source impedance, maximum power needs Z_L = Z_s^*, giving P_{max} = \frac{V^2}{4R_s}.
With both R_L and X_L adjustable, maximum power occurs for Z_L = Z_s^* = 3 - j4\ \Omega. The reactances cancel, leaving a total resistance of 6\ \Omega and I = \frac{100}{6} = 16.67\ \text{A}.
P = I^2R_L = 277.8\times3 = 833.3\ \text{W}.
Check: P_{max} = \frac{V^2}{4R_s} = \frac{10000}{12} = 833.3\ \text{W}. ✓
Common mistake: Choosing Z_L = Z_s (reactances add) gives I = \frac{100}{|6+j8|} = 10\ \text{A} and only 300\ \text{W}.
You need: Maximum power transfer; complex conjugate
Q.11
MediumMCQ2 marks
A load has voltage and current . The average power and reactive power absorbed are
Show answer and solutionHide answer and solution
Answer: (A)
Key idea: The power angle is the voltage phase minus the current phase.
The rms values are V = 200\ \text{V} and I = 10\ \text{A}. The phase angle is \phi = \theta_v - \theta_i = 10^\circ - (-20^\circ) = 30^\circ, so the current lags.
P = VI\cos30^\circ = 2000\times0.866 = 1732\ \text{W} and Q = VI\sin30^\circ = 2000\times0.5 = 1000\ \text{var}, inductive.
Common mistake: Subtracting in the wrong order gives -30^\circ, which reads as capacitive (B). Using \cos60^\circ and \sin60^\circ gives (D).
You need: Phasors; power angle
Q.12
MediumMSQ2 marks
An inductive load is supplied at a fixed rms voltage. A capacitor is connected in parallel with it, and the load itself is unchanged. Which of the following statements are correct?
One or more options are correct.
Show answer and solutionHide answer and solution
Answer: (A) and (C)
Key idea: A parallel capacitor changes Q but not P, so it lowers the current.
(A) is true: the capacitor supplies reactive power, which reduces |Q| at the source while P is unchanged, so |S| and the current fall. (B) is false: the load is unchanged, so it still absorbs the same real power. (C) is true: an ideal capacitor absorbs no real power. (D) is false: a series capacitor changes the voltage across the load, so the load's P and Q would change.
Common mistake: Believing that power factor correction reduces the useful real power.
You need: Power factor correction; ideal capacitor
Q.13
HardNAT2 marks
A load absorbs at lagging while its terminal voltage is held at rms. It is fed through a line of resistance (no reactance). The rms voltage magnitude at the source end of the line, in volts, is ______.
Numerical answer: type a number.
Show answer and solutionHide answer and solution
Answer: 410.07 V (accepted 410 to 410.2)
Key idea: Use phasors with the load voltage as reference; the line drop adds as a complex number.
The load apparent power is S = \frac{8}{0.8} = 10\ \text{kVA}, so I = \frac{10000}{400} = 25\ \text{A}. Take the load voltage as reference, 400\angle0^\circ. The current lags by 36.87^\circ: I = 25(0.8 - j0.6) = 20 - j15\ \text{A}.
The source voltage is V_s = 400 + 0.5(20 - j15) = 410 - j7.5\ \text{V}, so |V_s| = \sqrt{410^2+7.5^2} = 410.07\ \text{V}.
Check by power: the line loss is 25^2\times0.5 = 312.5\ \text{W}. The source supplies P = 8312.5\ \text{W} and Q = 6000\ \text{var}, so S = 10251.7\ \text{VA} and |V_s| = \frac{10251.7}{25} = 410.07\ \text{V}. ✓
Common mistake: Adding the line drop magnitude directly, 400 + 0.5\times25 = 412.5\ \text{V}.
You need: Phasor KVL; complex power
Q.14
HardNAT2 marks
Two loads are connected in parallel across a rms supply. Load A draws at lagging. Load B absorbs at leading. The rms current drawn from the supply, in amperes, is ______.
Numerical answer: type a number.
Show answer and solutionHide answer and solution
Answer: 14.14 A (accepted 14.1 to 14.2)
Key idea: Add P and Q with signs: lagging is positive and leading is negative.
Load A: P_A = 5\times0.6 = 3\ \text{kW} and Q_A = 5\times0.8 = +4\ \text{kvar}.
Load B: S_B = \frac{4}{0.8} = 5\ \text{kVA} and Q_B = -\sqrt{25-16} = -3\ \text{kvar} (leading).
Totals: P = 7\ \text{kW} and Q = 4 - 3 = 1\ \text{kvar}, so |S| = \sqrt{49+1} = 7.071\ \text{kVA}. Then I = \frac{7071}{500} = 14.14\ \text{A}.
Check with currents: each load draws \frac{5000}{500} = 10\ \text{A}. I_A = 10\angle-53.13^\circ = 6 - j8 and I_B = 10\angle36.87^\circ = 8 + j6. The sum is 14 - j2, and |I| = \sqrt{196+4} = 14.14\ \text{A}. ✓
Common mistake: Adding the apparent powers, 5 + 5 = 10\ \text{kVA}, gives 20\ \text{A}.
You need: Power triangle; leading and lagging loads
Q.15
HardMCQ2 marks
A load of at lagging is connected to a supply. By mistake a capacitor bank rated at the supply voltage is connected in parallel with it. The power factor seen by the supply is now
Show answer and solutionHide answer and solution
Answer: (B)
Key idea: Too much capacitance overcorrects, so the net reactive power changes sign and the power factor becomes leading.
The load reactive power is Q = 20\times0.75 = 15\ \text{kvar} (lagging). The capacitor supplies 20\ \text{kvar}, so the net reactive power is 15 - 20 = -5\ \text{kvar}.
|S| = \sqrt{20^2+5^2} = 20.62\ \text{kVA}, and the power factor is \frac{20}{20.62} = 0.970. Since the net Q is negative, the supply current leads: overcorrection.
Common mistake: Assuming the result is still lagging because the load is inductive, which gives (A).
You need: Power factor correction; sign of Q
Past GATE questions on this topic
- GATE 2026 EC, Q.31: Parallel RLC resonance (1 mark, NAT)