Sampling, Quantization and PCM: GATE ECE practice questions with solutions
This topic covers the Nyquist rate, aliasing, band-pass sampling, quantization noise, PCM and TDM rates and delta modulation. The 15 original questions follow the GATE EC format: 9 MCQ, 2 MSQ and 4 NAT, from 5 easy, 7 medium and 3 hard.
Three ideas to know:
- The Nyquist rate is twice the highest frequency present.
- When f_H is an integer multiple of B, a band-pass signal can be sampled at 2B.
- Slope overload is avoided when the signal's steepest slope is within one step per sample.
It helps GATE EC and ECE students revising Communications for the exam or a semester test. Helpful background: Quantization noise and PCM. Start with the 5 easy questions, then work up to the 3 hard ones.
Related
Q.1
EasyMCQ1 mark
The Nyquist rate of x(t) = cos(400πt) + sin(1000πt) is
Show answer and solutionHide answer and solution
Answer: (B)
Key idea: The Nyquist rate is twice the highest frequency present.
1. The components are at 200 Hz and 500 Hz.
2. Nyquist rate = 2 × 500 = 1000 Hz.
Common mistake: Quoting the highest frequency itself, 500 Hz, option (A).
You need: Sampling theorem
Q.2
EasyMCQ1 mark
An 8-bit uniform quantizer covers the range −5 V to +5 V with 256 levels. The step size is closest to
Show answer and solutionHide answer and solution
Answer: (A)
Key idea: The step size is the full peak-to-peak range divided by the number of levels.
1. Full range = 10 V. 2. Δ = 10/2⁸ = 10/256 = 39.1 mV.
Common mistake: Using only the positive half, 5/256 = 19.5 mV, option (C).
You need: Uniform quantization
Q.3
EasyNAT1 mark
A full-scale sinusoid is quantized by a 10-bit uniform quantizer. Using SQNR = 6.02n + 1.76 dB, the SQNR is ______ dB (round to one decimal place).
Numerical answer: type a number.
Show answer and solutionHide answer and solution
Answer: 62 (accepted 61.9 to 62.1)
Key idea: Each bit adds about 6 dB; the 1.76 dB term comes from the sinusoid's power relative to its peak.
1. SQNR = 6.02 × 10 + 1.76. 2. = 60.2 + 1.76 = 61.96 dB.
Common mistake: Leaving out the 1.76 dB term gives 60.2 dB.
You need: Quantization noise
Q.4
EasyMCQ1 mark
A voice signal band-limited to 4 kHz is sampled at its Nyquist rate and each sample is coded with 8 bits. The PCM bit rate is
Show answer and solutionHide answer and solution
Answer: (D)
Key idea: Bit rate = samples per second × bits per sample.
1. Sampling rate = 2 × 4 = 8 kHz.
2. Bit rate = 8000 × 8 = 64 kbit/s.
Common mistake: Sampling at the bandwidth 4 kHz instead of twice it gives 32 kbit/s, option (A).
You need: PCM
Q.5
EasyMCQ1 mark
A 7 kHz tone is sampled at 10 kHz and then reconstructed with an ideal low-pass filter of cutoff 5 kHz. The output tone frequency is
Show answer and solutionHide answer and solution
Answer: (B)
Key idea: Undersampling folds a tone to |f − k fs|, the copy that lands in the baseband.
1. Spectral copies appear at k × 10 ± 7 kHz: 3, 7, 13, 17 kHz and so on.
2. Only 3 kHz lies below the 5 kHz cutoff.
3. The output is a 3 kHz tone.
Common mistake: Assuming the original 7 kHz tone comes through, option (A), although it lies above the filter cutoff.
You need: Aliasing
Q.6
MediumMCQ1 mark
A band-pass signal occupies 20 kHz to 25 kHz. Using band-pass sampling, fs = 2f_H/⌊f_H/B⌋, the minimum alias-free sampling rate is
Show answer and solutionHide answer and solution
Answer: (C)
Key idea: When f_H is an integer multiple of B, a band-pass signal can be sampled at 2B.
1. B = 5 kHz and f_H = 25 kHz, so f_H/B = 5 exactly. 2. fs = 2 × 25/5 = 10 kHz.
Common mistake: Applying the low-pass rule 2f_H = 50 kHz, option (A).
You need: Band-pass sampling
Q.7
MediumNAT1 mark
A uniform quantizer has step size 0.1 V and the input is busy enough that the error is uniform over one step. The rms quantization error is ______ mV (round to one decimal place).
Numerical answer: type a number.
Show answer and solutionHide answer and solution
Answer: 28.9 (accepted 28.8 to 29)
Key idea: The quantization noise power is Δ²/12.
1. Error uniform on (−Δ/2, Δ/2): mean-square value Δ²/12. 2. rms = Δ/√12 = 0.1/3.464 = 28.9 mV.
Common mistake: Using the peak error Δ/2 = 50 mV as the rms value.
You need: Uniform distribution, quantization
Q.8
MediumMCQ2 marks
Flat-top sampling holds each sample for the full sampling period Ts, giving the aperture response H(f) = Ts sinc(fTs). Relative to DC, the aperture attenuation at f = fs/2 is closest to
Show answer and solutionHide answer and solution
Answer: (D)
Key idea: The hold acts as a filter with a sinc magnitude, causing the aperture effect.
1. At f = fs/2, fTs = 0.5. 2. sinc(0.5) = sin(π/2)/(π/2) = 2/π = 0.637. 3. 20 log₁₀ 0.637 = −3.92 dB.
Common mistake: Using 10 log₁₀ for an amplitude ratio gives −1.96 dB, option (C).
You need: Flat-top sampling, decibels
Q.9
MediumMSQ2 marks
Which of the following statements about PCM are correct?
One or more options are correct.
Show answer and solutionHide answer and solution
Answer: (A), (C) and (D)
Key idea: In PCM, SQNR grows exponentially with n while bandwidth grows only linearly.
1. Δ halves with each bit, so noise power falls by 4 (6 dB): (A) true.
2. Bandwidth is proportional to n, so going from n to n + 1 bits scales it by (n + 1)/n, not 2: (B) false.
3. Companding uses finer steps near zero: (C) true.
4. (D) is the standard model.
Common mistake: Confusing the doubling of the number of levels with a doubling of the bandwidth, statement (B).
You need: PCM trade-offs, companding
Q.10
MediumMCQ2 marks
A TDM-PCM system multiplexes 30 channels, each sampled at 8 kHz with 7 bits per sample. Each frame carries one sample from every channel plus 2 framing bits. The line bit rate is
Show answer and solutionHide answer and solution
Answer: (B)
Key idea: Framing bits are sent once per frame, at the frame rate.
1. Bits per frame: 30 × 7 + 2 = 212.
2. Frames per second: 8000.
3. Rate = 212 × 8000 = 1.696 Mbit/s.
Common mistake: Leaving out the framing bits gives 210 × 8000 = 1.680 Mbit/s, option (A).
You need: Time-division multiplexing
Q.11
MediumNAT2 marks
A full-scale sinusoid is to be coded by uniform PCM with SQNR of at least 40 dB. Using SQNR = 6.02n + 1.76 dB, the minimum number of bits per sample is ______.
Numerical answer: type a number.
Show answer and solutionHide answer and solution
Answer: 7
Key idea: Always round the number of bits up.
1. 6.02n + 1.76 ≥ 40 gives n ≥ 38.24/6.02 = 6.35. 2. n must be a whole number, so n = 7 (SQNR 43.9 dB; n = 6 gives only 37.9 dB).
Common mistake: Rounding 6.35 down to 6, which gives only 37.9 dB.
You need: Quantization SQNR
Q.12
MediumMCQ2 marks
A 3.4 kHz voice signal is sampled at 8 kHz and coded with 8 bits per sample. Using ideal Nyquist (sinc) pulses, the minimum transmission bandwidth is
Show answer and solutionHide answer and solution
Answer: (C)
Key idea: Binary signaling needs at least half the bit rate in hertz.
1. Bit rate = 8000 × 8 = 64 kbit/s.
2. Minimum bandwidth with Nyquist pulses = Rb/2 = 32 kHz.
Common mistake: Setting the bandwidth equal to the bit rate, 64 kHz, option (A).
You need: Nyquist bandwidth, PCM
Q.13
HardMCQ2 marks
A delta modulator has step size 0.1 V and sampling rate 64 kHz. The largest amplitude of a 2 kHz sine wave that avoids slope overload is closest to
Show answer and solutionHide answer and solution
Answer: (A)
Key idea: Slope overload is avoided when the signal's steepest slope is within one step per sample.
1. The staircase can rise at most δfs = 0.1 × 64000 = 6400 V/s.
2. The sine's peak slope is 2πfmA.
3. A ≤ 6400/(2π × 2000) = 0.51 V.
Common mistake: Using fmA for the slope (no 2π) gives 6400/2000 = 3.2 V, option (B).
You need: Delta modulation
Q.14
HardNAT2 marks
The signal x(t) = cos(2π·1000t) + cos(2π·6500t) + cos(2π·9000t) is sampled at 8 kHz (no anti-aliasing filter) and reconstructed with an ideal low-pass filter of cutoff 4 kHz and gain chosen so that a tone below 4 kHz is returned unchanged. The average power of the reconstructed signal is ______.
Numerical answer: type a number.
Show answer and solutionHide answer and solution
Answer: 2.5
Key idea: An alias that lands on an existing tone adds by amplitude, not by power.
1. 6500 Hz aliases to 8000 − 6500 = 1500 Hz. 2. 9000 Hz aliases to 9000 − 8000 = 1000 Hz, and its samples cos(2π·9000n/8000) equal cos(2π·1000n/8000), so they add in phase to the 1000 Hz tone.
3. Output: 2cos(2π·1000t) + cos(2π·1500t).
4. Power = 4/2 + 1/2 = 2.5.
Common mistake: Treating the three tones as separate outputs of power 0.5 each gives 1.5.
You need: Aliasing, power of sinusoids
Q.15
HardMSQ2 marks
A uniform 8-bit quantizer is designed for a full-scale sinusoid. Using SQNR = 6.02n + 1.76 dB at full scale, which of the following statements are correct?
One or more options are correct.
Show answer and solutionHide answer and solution
Answer: (A), (B) and (C)
Key idea: For uniform quantization the noise is fixed, so SQNR follows the signal power.
1. 6.02 × 8 + 1.76 = 49.9 dB.
2. Halving the amplitude cuts signal power by 4 (6.02 dB) while noise is unchanged: 43.9 dB.
3. Halving Δ cuts noise power Δ²/12 by 4: +6 dB.
4. (D) uses a 3 dB drop and is false.
Common mistake: Treating halved amplitude as halved power (−3 dB) gives 46.9 dB, statement (D).
You need: Quantization noise, decibels
Past GATE questions on this topic
- GATE 2024 EC, Q.57: Quantisation SNR (2 marks, NAT)